CYECT1-11N Electronic Combined Transformer (CT&PT)

The products have designed base on IEC60044-8, GB/T20840.8-2007&IEC60044-7,GB/T20840.7-2007 standards, and customers special design service. This series are utilized LPCT&Rogowski coil to meter current in circle, conduct Resistor divider to measure voltage. Installed in any switchgear with High tense voltage below 10kV, compatible with electric instrument, digital measure and protective equipment, able to conduct multifunction such as measure, control, protection and data transmission etc simultaneity.



  • 产品描述
  • 规格参数
  • 资料下载

Main technical parameter
1
Rated primary voltage : 10/√3kV
2
Rated primary current : 50-1500A
3
Rated secondary output :
   ECT
:  4V (measure),  200mV (protection )
   EVT
: 1/√3V, 3.25/√3V  or  6.5/√3V
4
Rated digital output : 0x2D41( measure)0x01CF(protection)
5
Accuracy for measure winding : 0.2
6
Accuracy for protection winding : 5TPE(ECT)3P(EVT)
7
Rated frequency : 50Hz
8
Rated insulation level : 12/42/75kV
9
Rated short time thermal current : 50-200: 150Ipr, 300-1500A :31.5kA/1S
10
Rated dynamic current : 50-200A :375Ipr, 300-1500A :80kA
11
Ambient temperature : -5℃-40℃(indoor), -25℃-50℃(outdoor)
12
Ambient humidity : ≤RH95%(25℃)
13
Altitude : ≤ 2000m
14
Installation site : indoor/ outdoor

Outline drawing